The Design for the New Image Quality Indicator of Duplex Wire Type
![](/skin/Gold/line_sep1.gif)
摘 要
从射线检测的一般理论,提出了新型双丝像质计设计的理论。试验证明,所提出的理论可以用于指导新型双丝像质计的设计。该像质计可克服标准型双丝像质计只能得到一些特定的不清晰度值问题,并可测量更大范围的不清晰度。
![](flash/relate.gif)
![](flash/relate.gif)
![](flash/relate.gif)
![](flash/relate.gif)
![](flash/relate.gif)
![](flash/relate.gif)
![](flash/relate.gif)
![](flash/relate.gif)
![](flash/relate.gif)
![](flash/relate.gif)
Abstract
The theory for designing image quality indicator of duplex wire type was given on the basic theory of radiography. The theory of design had been shown as ture by the experiment. The new image quality indicator of duplex wire type enabled not only to determine more wide unsharpness value than the standard type, but it cleared out also the problem that the value of unsharpness determined was only specific by standard image quality indicator of duplex wire type.
中图分类号 TG115.28
所属栏目 科研成果与学术交流
基金项目
收稿日期 2006/12/3
修改稿日期
网络出版日期
![](/skin/blank.gif)
作者单位点击查看
![](/skin/blank.gif)
备注郑世才(1941-),男,研究员,长期从事射线检测工作,著有多本射线检测书籍和论文。
引用该论文: ZHENG Shi-cai. The Design for the New Image Quality Indicator of Duplex Wire Type[J]. Nondestructive Testing, 2007, 29(12): 701~704
郑世才. 新型双丝像质计设计[J]. 无损检测, 2007, 29(12): 701~704
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
![请选择您对本文的评价](/skin/Gold/evaluation/ev_01.gif)
![您认为本文一无是处!](/skin/Gold/evaluation/ev_02.gif)
![您认为本文较差,没啥用!](/skin/Gold/evaluation/ev_03.gif)
![您认为本文一般,没太大参考价值](/skin/Gold/evaluation/ev_04.gif)
![您认为本文尚可,值得参考](/skin/Gold/evaluation/ev_05.gif)
![您认为本文很好,值得推荐](/skin/Gold/evaluation/ev_06.gif)
参考文献
【1】BS 3971:1980 Image quality indicators for industrial radiography[S].
【2】EN 462-5:1996 Non-destructive testing-Image quality of radiographs Part 5: Image quality indicators(duplex wire type), determination of image unsharpness value[S].
【3】ASTM E2002—1998(2003) Standard practice for determining total image unsharpness in radiology[S].
【4】ISO 19232-5:2004 Non-destructive testing-Image quality of radiographs Part 5: Image quality indicators(duplex wire type), determination of image unsharpness value[S].
【5】郑世才.射线检测[M].北京:机械工业出版社,2004.
【2】EN 462-5:1996 Non-destructive testing-Image quality of radiographs Part 5: Image quality indicators(duplex wire type), determination of image unsharpness value[S].
【3】ASTM E2002—1998(2003) Standard practice for determining total image unsharpness in radiology[S].
【4】ISO 19232-5:2004 Non-destructive testing-Image quality of radiographs Part 5: Image quality indicators(duplex wire type), determination of image unsharpness value[S].
【5】郑世才.射线检测[M].北京:机械工业出版社,2004.
相关信息