Uncertainty Evaluation on Testing Results of Each Core Conductor Direct Current Resistance
![](/skin/Gold/line_sep1.gif)
摘 要
依据GB/T 3048.4-2007《电线电缆电性能试验方法 第4部分 导体直流电阻试验》, 采用双臂电桥法对某标称截面为2.5 mm2的单芯铜电线20 ℃时每千米长度的电阻值进行了测定, 并对试验过程中影响测定结果的各不确定度分量进行了评定。结果表明: 该单芯铜电线20 ℃时每千米长度的电阻值为R20=(7.837±0.023) Ω·km-1,k95=1.96。
![](flash/relate.gif)
![](flash/relate.gif)
![](flash/relate.gif)
![](flash/relate.gif)
![](flash/relate.gif)
![](flash/relate.gif)
Abstract
According to GB/T 3048.4-2007 “Test Methods for Electrical Properties of Electric Cables and Wires-Part 4: Test of DC Resistance of Conductors”, the DC resistance value per kilometre at 20 ℃of a 2.5 mm2 single core copper wire was measured by using arm bridge method. And uncertainty components which might affect the measurement results were evaluated. The results show that the DC resistance value per kilometre at 20 ℃ of the single core copper wire was R20= (7.837±0.023) Ω·km-1, k95=1.96.
中图分类号 TM934.1
所属栏目
基金项目
收稿日期 2011/1/27
修改稿日期
网络出版日期
![](/skin/blank.gif)
作者单位点击查看
![](/skin/blank.gif)
备注朱海波(1976-),男,工程师,学士。
引用该论文: ZHU Hai-bo. Uncertainty Evaluation on Testing Results of Each Core Conductor Direct Current Resistance[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2011, 47(8): 502~504
朱海波. 每芯导体电阻值测定结果的不确定度评定[J]. 理化检验-物理分册, 2011, 47(8): 502~504
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
![请选择您对本文的评价](/skin/Gold/evaluation/ev_01.gif)
![您认为本文一无是处!](/skin/Gold/evaluation/ev_02.gif)
![您认为本文较差,没啥用!](/skin/Gold/evaluation/ev_03.gif)
![您认为本文一般,没太大参考价值](/skin/Gold/evaluation/ev_04.gif)
![您认为本文尚可,值得参考](/skin/Gold/evaluation/ev_05.gif)
![您认为本文很好,值得推荐](/skin/Gold/evaluation/ev_06.gif)
参考文献
【1】JJF 1059-1999测量不确定度评定与表示[S].
相关信息