搜索热:裂纹 硫酸
扫一扫 加微信
首页 > 期刊论文 > 论文摘要
金属材料夏比冲击试样V型缺口的测量精度
          
Measurement Accuracy of V-notch of Charpy Impact Specimens for Metallic Materials

摘    要
金属材料夏比冲击试样V型缺口测量不规范导致冲击试验测试值严重失准, 比例图形绘制的精度及正确画法是保证冲击试样尺寸和形状完全满足GB/T229-2007规定的重要手段, 因此要严格控制夏比冲击试样V型缺口的测量精度, 用于缺口投影仪检验缺口质量和加工精度的标准公差带图形的绘制要统一标准。
标    签 夏比V型缺口冲击试样   测量精度   标准公差带图形   冲击试样缺口投影仪   Charpy V-notch impact specimen   measurement precision   standard tolerance zone graphics   impact specimens gap projector  
 
Abstract
Non-standard measurement of Charpy V-notch impact specimens of metallic material led to test value discrepancy seriously, and the precision of proportion graphics and the corret drawing were important means to guarantee the size and shape of impact specimens fully meet with the requirement of GB/T229-2007. So the measurement accuracy of Chapy V-notch impact specimens should be strictly controlled, the standards for inspecting notch quality with gap projector and drawing of standard figure of processing precision should be unified.

中图分类号 TG115.5+6

 
  中国光学期刊网论文下载说明


所属栏目

基金项目

收稿日期 2011/4/22

修改稿日期

网络出版日期

作者单位点击查看

备注付铁钢(1967-),男,工程师。

引用该论文: FU Tie-gang. Measurement Accuracy of V-notch of Charpy Impact Specimens for Metallic Materials[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2011, 47(8): 505~507
付铁钢. 金属材料夏比冲击试样V型缺口的测量精度[J]. 理化检验-物理分册, 2011, 47(8): 505~507


被引情况:


【1】杨 震,郭 勇,王 伟,于昭亮,王双龙,裴洪磊,徐婷婷, "一种用于冲击试验缺口试样对中的定位工装",理化检验-物理分册 52, 251-252(2016)



论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】王冲. 金属材料冲击试验的介绍[J]. 江苏锅炉,2010(3):26-29.
 
【2】骆志高,陈保磊,庞朝利. 金属基复合材料减磨抗冲击性能试验研究[J]. 材料导报,2009,23(18):33-35.
 
【3】于久灏,刘伟,穆文贺. 金属材料动态断裂试验接触状态研究[J]. 黑龙江工程学院学报(自然科学版),2010,34(3):69-71.
 
相关信息
   标题 相关频次
 GB/T 229-2007关于夏比V型缺口冲击试样几何参数的规定及其加工方法
 2
 电位法测试导体表面裂纹深度研究
 1
 国内外标准对夏比V型冲击试样的加工要求及其质量控制
 1
 金属材料弹性模量的仪器化压入测试
 1
 热导性电绝缘界面材料热传输特性参数的测量
 1